PHONOR SELECT BASIC
THE ROBUST HEARING PROTECTION SYSTEM
The Phonor Select Basic hearing protection system is made from silicone-free acrylate and is particularly suitable for dirty and dusty working environments.
| Individual hearing protection PHONOR SELECT BASIC | |
|---|---|
| Otoplasik with handle | Rigid | 
| Material | Acrylate | 
| Wearing time (recommended)* | 5 years* | 
| Skin/tolerance | Ph skin neutral | 
| Detector capability | in version with detector ball | 
| Approval (recommendation IFA table) | S, V, W and E approval | 
| *depending on the working environment, contact with chemical agents and possible anatomical changes to the ears | |

| Features & Quick Info | |
|---|---|
| Otoplastik | Filtertechnik | 
| High-quality earmolds with a perfect fit thanks to individual fabrication | for different work situations | 
| Unique assignment of the wearer thanks to lasered serial number | Perception of signal tones | 
| Very high wearer acceptance | Easy cleaning of the filters by blowing them out | 
| Particularly resistant to dirt / filter technology | |


FILTER FOR THE PHONOR SELECT BASIC
OVERVIEW OF POSSIBLE APPLICATIONS FOR PHONOR SELECT BASIC FILTER
The Phonor Select filters were developed particularly for applications in industry and trade. In order to determine the right filter for the individual user, a precise analysis of the noise situation is required. Possible areas of application include: B. Construction industry, mining industry, printing houses, wood processing.
| PHONOR SELECT BASIC | |||||||
|---|---|---|---|---|---|---|---|
| Filter | SNR value | H-value | M-value | L-value | Filter color | Areas of application | Figure | 
| PS0 | 31 | 32 | 28 | 25 | black | WSVE1 |  | 
| PS1 | 32 | 31 | 30 | 26 | white | WSVE1 |  | 
| PS2 | 26 | 27 | 23 | 19 | silver | W |  | 
| PS3 | 23 | 26 | 20 | 16 | blue | - |  | 
| H/M/L values taking into account the assumed standard deviations | |||||||
*) SNR value
The SNR value (Simplified Noise Reduction), measured in dB, indicates the average attenuation in the entire frequency range analyzed (i.e. 125 – 8000 Hz).
Frequency ranges in Hz:
H = high frequency (2000 – 8000 Hz) M = medium frequency (500 – 2000 Hz) L = low frequency (125 – 500 Hz)
Tested at PZT GmbH (1974), An der Junkerei 48, D-26389 Wilhelmshaven / GER on May 18, 2016 under test number 771603-1. Further information can be requested from the manufacturer.
In workplaces where hearing protection is used, ambient noise must usually remain audible. Important aspects when selecting suitable hearing protection are the audibility of warning signals and information-containing work noises as well as speech intelligibility at the workplace. As an aid to selection, the IFA positive list (list of all hearing protectors reported to the IFA with an EC type examination certificate) contains additional indicators for signal audibility. The IFA determines the characteristics from the average values of the sound insulation that were measured during the type testing of the hearing protectors.
| Areas of application according to IFA positive list | |
|---|---|
| W | Warning signals: Criteria "Hearing warning signals in general", "Information-containing noises" and "Speech intelligibility" fulfilled | 
| X | Extremely low-attenuation hearing protection. Suitable for people with hearing loss. | 
| S | Signal listening possible in the track superstructure | 
| V | Roadworthiness: signal hearing possible for drivers in road traffic | 
| E | Railroad operations: Hearing signals possible for train drivers and engine drivers in railroad operations E1= Very suitable (especially for people with hearing impairment), E3= Conditionally suitable | 
PHONOR SELECT COMFORT
OUR TOP SELLER
Hearing protection system with high wearing comfort for most industrial applications
| Individual hearing protection PHONOR SELECT COMFORT | |
|---|---|
| Otoplasik with handle | Soft | 
| Material | Silikon (60 Shore) | 
| Wearing time (recommended)* | 5 Years* | 
| Skin/tolerance | Ph skin neutral | 
| Detector capability | in version with detector ball | 
| Approval (recommendation IFA table) | S, V, W and E approval | 
| * depending on the working environment, contact with chemical agents and possible anatomical changes to the ears | |

| Features & Quick Info | |
|---|---|
| Otoplasty | Filter technology | 
| High-quality earmolds with a perfect fit thanks to individual fabrication | Less attenuation at 4000 Hz, resulting in better speech intelligibility | 
| Unique assignment of the wearer thanks to lasered serial number | Individual filter selection for different work situations | 
| Very high wearer acceptance | Perception of signal tones | 
| Soft silicone material also increases wearing comfort | Easy cleaning of the filters by blowing them out | 


FILTER FOR THE PHONOR SELECT COMFORT
OVERVIEW OF POSSIBLE APPLICATIONS FOR PHONOR SELECT COMFORT FILTER
| PHONOR SELECT COMFORT | |||||||
|---|---|---|---|---|---|---|---|
| Filter | SNR-value | H-value | M-value | L-value | Filter color | Areas of application | Figure | 
| PS0 | 27 | 28 | 24 | 22 | black | WXSVE1 |  | 
| PS1 | 27 | 28 | 24 | 22 | white | WXSE |  | 
| PS2 | 25 | 26 | 22 | 18 | silver | W |  | 
| PS3 | 20 | 24 | 17 | 11 | blue | - |  | 
| H/M/L values taking into account the assumed standard deviations | |||||||
*) SNR value
The SNR value (Simplified Noise Reduction), measured in dB, indicates the average attenuation in the entire frequency range analyzed (i.e. 125 – 8000 Hz).
Frequency ranges in Hz:
H = high frequency (2000 – 8000 Hz) M = medium frequency (500 – 2000 Hz) L = low frequency (125 – 500 Hz)
Tested at PZT GmbH (1974), An der Junkerei 48, D-26389 Wilhelmshaven / GER on May 18, 2016 under test number 771603-1. Further information can be requested from the manufacturer.
In workplaces where hearing protection is used, ambient noise must usually remain audible. Important aspects when selecting suitable hearing protection are the audibility of warning signals and information-containing work noises as well as speech intelligibility at the workplace. As an aid to selection, the IFA positive list (list of all hearing protectors reported to the IFA with an EC type examination certificate) contains additional indicators for signal audibility. The IFA determines the characteristics from the average values of the sound insulation that were measured during the type testing of the hearing protectors.
| Areas of application according to IFA positive list | |
|---|---|
| W | Warning signals: Criteria "Hearing warning signals in general", "Information-containing noises" and "Speech intelligibility" fulfilled | 
| X | Extremely low-attenuation hearing protection. Suitable for people with hearing loss. | 
| S | Signal listening possible in the track superstructure | 
| V | Roadworthiness: signal hearing possible for drivers in road traffic | 
| E | Railroad operations: Hearing signals possible for train drivers and engine drivers in railroad operations E1= Very suitable (especially for people with hearing impairment), E3= Conditionally suitable | 